logo

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Power Cable
Created with Pixso.

VFD Double shield cables for steel factory -ZR-BPYJVRP

VFD Double shield cables for steel factory -ZR-BPYJVRP

Brand Name: ECHU
Model Number: ZR-BPYJVRP
MOQ: 300M
Price: USD0.103-USD0.883/m
Payment Terms: T/T, Western Union
Supply Ability: 100000km/week
Detail Information
Place of Origin:
China
Certification:
CE
Conductor:
Copper
Insulation:
XLPE
Jacket:
PVC
Voltage:
0.6/1JV
Packaging Details:
Splint reel
Product Description

Application:

The cable is used as power supply cables or electrical connection of inverter control system at AC rated voltage 0.6/1KV or less

 

Working Condition:

1.AC rated voltage Uo/U:0.6/1KV

2.Max working temperature PVC insulation is 70ºC,XLPE insulation is 90ºC

3.Min. enviroment temperature XLPE sheathed cable shall be not less than -70ºC ,PVC sheath cable shall be not less than -25ºC

4.Enviroment temperature shall be not less than 0ºC for cable in-stallation.

5.Min.bending radius for installation shall be 15 times outer diameter of cable.

 

Type and Name:

Type name
BPVVP PVC insulated and sheathed copper wire braided shield frequency converter power cable
BPVVP2 PVC insulated and sheathed copper tape wrapped shielding frequency converter power cable
BPVVPP2

PVC insulated and sheathed copper wire braided copper tape wrapped shield

frequency converter power cable

BPVVP3

PVC insulated and sheathed aluminum polyester composite film wrapped and shielded

frequency converter power cable

BPYJVP XLPE insulated PVC sheathed copper wire braided shield frequency changer power cable
BPYJVP2 XLPE insulated PVC sheathed copper tape wrapped shield frequency changer power cable
BPYJVPP2

XLPE insulated PVC sheathed copper wire braided copper tape wrapped shield

frequency changer power cable

BPYJVP3

XLPE insulated PVC sheathed aluminum polyester composite film wrapped and shielded

frequency changer power cable

Note: Prefix ZR is added to the flame retardant type cable's code

 

Technical Requirement:

1.Conductor DC resitance of cable should comply with the requirement of GB/T3956-2008
2.Insulation resistance constant(20ºC,min):PVC insulation:36.7MΩ/KM
3.Cable should withstand AC voltage testing of 50HZ,3.5KV/5min,no breakdown

VFD Double shield cables for steel factory -ZR-BPYJVRP 0

Technical Requirement:

1.Conductor DC resitance of cable should comply with the requirement of GB/T3956-2008
2.Insulation resistance constant(20ºC,min):PVC insulation:36.7MΩ/KM
3.Cable should withstand AC voltage testing of 50HZ,3.5KV/5min,no breakdown

VFD Double shield cables for steel factory -ZR-BPYJVRP 0